Reverse Osmosis Membrane Cleaning Services
Reverse Osmosis membrane cleaning is an essential part in the routine maintenance process for protecting your investment commercial water treatment. Cleaning can prevent damage to your system while extending the life of your membranes, thus saving you money on replacements.
Membrane-based water treatment technologies that are prone to fouling, consist of reverse osmosis, microfiltration, nanofiltration, and ultrafiltration. Main causes of membrane fouling consist of a decline in your water quality, strong smell caused by biological growth on your membranes, and build up forming on the membrane edges.
For example, Increased pressure drops at the first stage of a filtration system usually signal fouling by colloidal, either inorganic or organic, or by bacteria. This is often managed by using a low pH soak followed by alkaline cleaning. Elevated pressure drops at the final stage indicate mineral deposition, which can be addressed by identifying the specific minerals involved. System or antiscalant projections, along with mineral analysis of the feed and concentrate, can guide the choice of cleaning agents—low-pH cleaners for carbonate scales and alkaline chelant cleaners for sulfate scales.
It is best practice to have reverse osmosis membranes cleaned when normalized flow decreases by 10-15% from the initial acceptance test conditions. It can be difficult to recover performance if the system has operated in a fouled condition for an extended period of time. Operating in a fouled condition can also cause irreversible damage to the membrane performance, which would require costly replacements if left unchecked.
Industrial Reverse Osmosis Parts
Engineered H2O Solutions carries a wide array of RO parts in stock. We even carry some obsolete parts in stock.
- Reverse Osmosis Pumps
- Reverse Osmosis Membrane Cleaning Chemicals
- Reverse Osmosis Membranes
- Pre-Filters
- UF Modules
- Solenoid Valves
- Conductivity Probes
- pH Probes
- Flow Meters
- Sample Ports
- Butterfly Valves
- UV Bulbs, Sleeves, O-rings, Ballast
- End Cap O-rings & Snap Rings
- Inter-connectors
- Membrane Brine Seals
- End Cap Adapters
- Pressure Gauges
- PLC & Controllers
- Motor Starters
https://www.dupont.com/knowledge/signs-of-membrane-fouling-and-when-to-clean-them.html